← Back to question bank

Packing non-shrink grout under an elastomeric bridge bearing, what field sign indicates a sound full bed?

Choices

  • (A) Visible air gaps along edges
  • (B) Grout appearing at vent ports with consistent rheology after head pressure per data sheet
  • (C) Never use side forms
  • (D) Dry-pack with minimal water

Correct answer: (B)

Grout appearing at vent ports with consistent rheology after head pressure per data sheet

Explanation

Port flow proves the pad is squeezed full without voids.

Back to question bank →

Question 171 of 176